Skip to content
Trade estimating

Brickwork takeoff for wall faces, openings and returns

Measure brickwork by the area of each leaf, the single thickness of brick shown in a wall section. Use the brick and joint dimensions to convert that area into units. The EstiFlow selector groups brickwork under Masonry.

Read each elevation one leaf at a time

Separate face brick from common brick and split walls where the brick size, bond or finish changes. Measure length and height between the levels shown. Deduct the openings in each leaf and use the jamb detail to measure any brick that returns into the opening.

Measure sill and head courses in metres or count the special units shown. Record lintels by length and type. Locate ties, cavity trays and movement joints from the wall details. If a feature course replaces plain brick, mark the area it replaces.

Illustrative takeoff for one brick leaf

Assume the face is 4.8 m long and 2.58 m high. Each brick with its mortar joint occupies 0.24 m along a course and 0.086 m in height. That gives 4.8 ÷ 0.24 = 20 brick lengths per course and 2.58 ÷ 0.086 = 30 courses, or 600 brick equivalents.

One opening lines up with the joints and removes five brick lengths through 15 courses. Deduct 5 × 15 = 75, leaving 525 brick equivalents in the flat face. This net count excludes reveal returns, special sill bricks, cuts and breakage.

Allocate support steel and cavity work

Check the steel schedule against lintels and shelf angles on the elevation. Identify who supplies each piece and who beds or fixes it. Check cavity insulation against the insulation package and assign scaffold access once for the elevations that need it.

Questions about this estimate

Can I double the outer face area for a cavity wall?

Measure both leaves from their own dimensions. The inner leaf may use a different unit, stop at a different level or form a different return. Keep its openings and unit count on its own line.

What if the brick has been selected but the joint is missing?

Record the net wall area and ask for the joint width and course height. If you issue a provisional count, show the assumed module beside it so the count can be revised.