Plasterboard takeoff by wall face, board type and layer
For plasterboard, measure the area of each lined face and multiply by the number of layers on that face. A partition can use a different board or layer count on either side. The EstiFlow selector calls this trade Plasterboard and ceilings.
Follow the wall type through the section
Record the board type, thickness and layer count for each side of the partition. Check whether the lining stops at the ceiling or continues to the underside of the slab. Measure the opening through each affected layer. Add lined reveals from their own width and depth.
Measure ceilings by board type and level. Break bulkheads into vertical sides and soffits. Trace cornices, shadow lines, corner beads and control joints in metres. Count access panels by size and check the detail for lining around the opening.
Illustrative takeoff for different layer counts
Assume a straight partition 5.4 m long and 2.7 m high. One opening passes through both faces and measures 0.9 m by 2.1 m. Each face has 5.4 × 2.7 = 14.58 m² gross. Deduct 1.89 m² to leave 12.69 m² per face.
The example wall schedule shows two layers on the corridor side and one on the room side. Allow 2 × 12.69 = 25.38 m² of corridor board and 12.69 m² of room board. That is 38.07 m² of board. Only the two outer faces are exposed, covering 25.38 m² in total. Record any treatment specified for the concealed layer separately.
Set the boundary at the frame and the finish
Identify who supplies wall studs, ceiling hangers, insulation and backing for fixtures. Check who cuts service openings and who seals them. Agree where the plasterer’s specified joint finish ends and the painter’s preparation begins.
Questions about this estimate
Can I turn total board area straight into a sheet order?
Group the areas by board type and thickness first. Lay the available sheet sizes against the wall height and joint layout. Track usable offcuts within each board type before rounding to whole sheets.
How do I measure a lining above a suspended ceiling?
Use the wall section to locate the top of the lining on each face. Measure the strip above the ceiling for each layer that continues. Check its finish requirements separately from the visible wall below.